TH5-NT SETUP INSTRUCTIONS 2015-07-22

A.    Scope of use

This transformer suit for all kinds of neon tubing (Mixture argon/neon gas)

B.    Installation requirement

1. Ensure the input voltage and frequency suited for the transformer

2.The transformer must be proper grounded

3. Minimize the length of HT cable

4. Keep the transformer away from the flammable material 

5.Ensure mounted transformer in the cool place

 

C.   Installation position

1.Any place in indoor

2.The unit should be mounted in the proper place

3.Ensure fix it properly when install on the wall or any place vertically to the ground.

4.Any improper operating shall void the warranty

 

D.       Principium of the transformer

 

E.       Connection

1.The input wire recommend use the >1.5mm2 plastic wire. Connect in L H

2.The out put cable must use the pressure-proof >15KV silicon cable and >0.5mm2 , connect to the output place.

3.Metallic conduit terminated in fittings listed for grounding all the way back to its breaker panel

4.ensure the screws tight when finish

 

F.       Specifications



     item

model

input

output

voltage (V)

voltage (KV)

current(mA)

TH5-NT-6

230 or 240

6

30

TH5-NT-7.5

7.5

30

TH5-NT-9

9

30

TH5-NT-12

12

30

TH5-NT-15

15

30

TH5-NT-7560

7.5

60

TH5-NT-1060

10

60



 

   The loaded lamp (tube) length can be adjusted to the maximum value listed below

 



       item

 

model

Tube diameter (mm)

9

10

11

12

13

14

15

18

20

Gas pressure (mmHg)

15

13

12

11

10

10

9

8

7.5

type

Maximum load length

TH5-NT-6

 

neon

feet

12

13

15

16

18

19

20

23

28

meter

3.66

3.96

4.57

4.88

5.49

5.79

6.10

7.01

8.53

mercury

feet

14

16

18

19

21

23

24

28

32

meter

4.27

4.88

5.49

5.79

6.40

7.01

7.32

8.53

9.75

TH5-NT-7.5

 

neon

feet

15

17

19

21

22

24

26

28

34

meter

4.57

5.18

5.79

6.40

6.71

7.32

7.92

8.53

10.36

mercury

feet

18

20

23

25

27

28

31

35

39

meter

5.49

6.10

7.01

7.62

8.23

8.53

9.45

10.67

11.89

TH5-NT-9

neon

feet

18

21

24

26

29

30

33

40

48

meter

5.49

6.40

7.32

7.92

8.84

9.14

10.06

12.19

14.63

mercury

feet

22

25

28

32

33

36

40

45

55

meter

6.71

7.62

8.53

9.75

10.06

10.97

12.19

13.72

16.76

TH5-NT-12

 

neon

feet

26

29

32

35

39

42

45

55

61

meter

7.92

8.84

9.75

10.67

11.89

12.80

13.72

16.76

18.60

mercury

feet

31

35

38

44

46

50

55

62

70

meter

9.45

10.67

11.58

13.41

14.02

15.24

16.76

18.90

21.34

TH5-NT-15

 

neon

feet

32

36

40

45

50

54

60

72

78

meter

9.75

10.97

12.19

13.72

15.24

16.46

18.29

21.95

23.77

mercury

feet

39

44

48

55

60

64

72

80

90

meter

11.89

13.41

14.63

16.76

18.29

19.51

21.95

24.38

27.43

TH5-NT-7560

 

neon

feet

 

 

 

 

 

 

26

28

34

meter

 

 

 

 

 

 

7.92

8.53

10.36

mercury

feet

 

 

 

 

 

 

31

35

39

meter

 

 

 

 

 

 

9.45

10.67

11.89

TH5-NT-1060

neon

feet

 

 

 

 

 

 

37

45

51

meter

 

 

 

 

 

 

11.30

13.75

15.67

mercury

feet

 

 

 

 

 

 

45

51

60

meter

 

 

 

 

 

 

13.75

15.50

18.18



 

 

Remark:

The maximum length in feet may vary according to output cable length and environment. Deduct one foot from above figures for each pair of electrodes while more than two tubes connected in series. Figures for mercury tubes are based on operation in temperature above 4°C. Deduct 25% value of above if operation below 4°C. Do not operate over the maximum value, otherwise the life time and performance of this device may be reduce

 